Automatic Newlab X Bath
Automatic Newlab X Bath
- Bench top instrument compact and solid structure painted with anti-epoxy products, include the refrigerator system (with Gas CFC free) and dedicated electronic board with the new Linetronic’s interchangeable head system for use different analytical heads with a single cooling bath.
- Analytical head support made in aluminium and corrosion resistant plastics, automatic up-middle-down movement with locking system.
- Safety systems: Overheating alarm and protection, over-pressure protection system, head wrong position protection, stand-by module for energy saving.
- Cooling Performance: able to grant working temperatures of -120°C …+55°C.
- Linetronic Management software running on 10” High-brightness TFT with resolution 1280 × 700:
- Pre-setting for methods ASTM / IP / ISO;
- Customizable analysis parameters;
- Settable bath temperature and controlled by PT100 A Class with 0,1°C precision;
- More than 60’000 analysis storage capacity;
- 2 × USB for connecting: mouse, keyboard and software updates;
- 1 × RJ45 Ethernet / Lims connection;
- Integrated beeper for end-test notification.
Weight
- 17
Small footprint
- Width 28 cm
- Depth 52 cm
- Height 50 cm
Power supply
- 220 or 115 Vac
NewLab X must be equipped with one (at least) of the following analitical head:
Freezing Point
Analitical Head 410 2.0
- Analytical head made in corrosion resistant plastics, automatic up-middle-down movement with locking system.
- Linetronic fixing system for glassware that allow an easy cleaning of all components.
- Integrated FP electronic board.
- Glassware included: Freezing glass cell.
- Fiber optic and PT100 sensor for Freezing Point temperature.
- Stirring motor and wire.
- Adapter for glassware.
Cloud and Pour
Analitical Head 1300 2.0
- Analytical head made in corrosion resistant plastics, automatic up-middle-down movement with locking system.
- Linetronic fixing system for glassware that allow an easy cleaning of all components.
- Integrated CPP electronic board.
- Glassware included: glass cell with silvered bottom.
- Fiber optic and PT100 sensor for Cloud Point temperature.
- PT100 sensors for Pour Point Detection and temperature.
Cloud Point of petroleum products and biodiesel fuels.
ASTM D5771
DIN 51597
EN 23015
EN 590
IP 444
Correlated:
ASTM D2500 – ASTM D5772 – ASTM D5773
IP 219 – IP 445 – IP 446
ISO 3015
JIS K2269
Cold Filter Plugging Point of diesel, biodiesel and heating fuels.
ASTM D6371
IP 309 – IP 419
EN 116 – EN 16329
Pour Point of petroleum products, crude oils, motor and engine oils, additives, lubricating oils, …
ASTM D97 – ASTM D5853 – ASTM D5950 – ASTM D6074 – ASTM D6158
IP 15 – IP 441
ISO 3016
EN ISO 22995
Freezing Point of aviation fuels, aviation gasoline, aviation turbine fuels, engine coolants, antifreeze products, brake fluids, … Solidification Point of Benzene. Solidification Point of Industrial Organic Chemicals.
ASTM D1655 – ASTM D2386
IP 16
Correlated:
ASTM D1493 – ASTM D5901 – ASTM D5972 – ASTM D6660 – ASTM D7153 – ASTM D7154
IP 435 – IP 528 – IP 529
ISO 3013
JIS K2276
DEF STAN91-091